Please use this identifier to cite or link to this item: http://hdl.handle.net/11458/2394
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorCasas Luna, Santiago Alberto
dc.contributor.authorRodas Hernandez, Jhorlin Eli
dc.date.accessioned2017-07-21T15:28:15Z
dc.date.available2017-07-21T15:28:15Z
dc.date.issued2017
dc.identifier.citationRodas-Hernandez, J. E. (2017). Propuesta de diseño de una planta de tratamiento de aguas residuales con decantación de flujo radial para reducir el grado de contaminación del cuerpo receptor, distrito de Yantaló – Moyobamba, 2015. Tesis para optar el grado de Ingeniero Sanitario. Facultad de Ecología, Universidad Nacional de San Martín, Tarapoto, Perú.es_PE
dc.identifier.urihttp://hdl.handle.net/11458/2394
dc.description.abstractEl presente trabajo titulado “Propuesta de diseño de una planta de tratamiento de aguas residuales con decantación de flujo radial para reducir los grados de contaminación del cuerpo receptor, distrito de Yantalo – Moyobamba, 2015”, es el resultado de la investigación, cálculos, dimensionamiento y diseño, de los análisis realizados a las aguas residuales del distrito ya mencionado. La problemática ambiental que se presenta en los municipios del Perú actualmente, es la contaminación ambiental por vertimiento de aguas residuales sin tratamiento alguno, es por ello que, se realizó una visita al municipio de Yantaló con el fin de monitorear los vertimientos de aguas residuales y hacer la correspondiente caracterización de estas aguas residuales, para establecer la tecnología más apropiada utilizando la metodología propuesta por el Ministerio del Ambiente y a partir de este análisis realizar los cálculos, dimensionamientos y finalmente el diseño de la Planta de Tratamiento de Agua Residual, los cuales incluyen pre tratamiento, tratamiento primario y tratamiento terciario Los parámetros principales para medir la eficiencia de la planta de tratamiento en el presente estudio, de acuerdo al D.S Nº 003-2010-MINAM. Aprueba Límites Máximos Permisibles para los efluentes de Plantas de Tratamiento de Aguas Residuales Domesticas o Municipales, publicado en el diario Oficial el Peruano el 17 de marzo de 2010, son: la DBO5, DQO, Solidos Suspendidos, Aceites y Grasas, Coliformes Totales, pH y temperatura. Al caracterizar las aguas residuales del distrito de Yantaló, se obtuvo resultados promedios, producto de 4 muestras analizadas en el Laboratorio Regional del Agua – Departamento de Cajamarca: 184.5 mg/L de DBO5, 318.5 mg/l de DQO, 191.13 de SST, 58.25x104 NMP/100ml de Coliformes Totales, 51 mg/l de aceites y grasas, los cuales se encuentran fuera de los Límites Máximos Permisibles (LMP’s) para su descarga final. La tecnología de tratamiento seleccionada para esta propuesta de diseño de una planta de tratamiento de aguas residuales consta de 5 componentes, Cámara de Rejas, desarenador, trampa de grasas, decantación primaria y desinfección (mamparas de cloración), de los cuales se tiene los siguientes valores de remoción: Rejilla (DBO5=5%, SST=25%), Desarenador (DBO5=15%, SST=30%), Desengrasador (DBO5=25%, SST=30%), Decantador de flujo radial (DBO5=49%, SST=70%), Desinfección (DBO5=15%, SST=0%). ix Se dimensionó el sistema de tratamiento de agua residual, que consista de un canal de 2 m. de largo y 0.30 m., con una rejilla en su estructura central a una inclinación de 45°, un desarenador de 6 m. con By-pass, y con canal parshall para medición de caudal, trampa de grasas, seguido de un decantador de flujo radial de 5.13 m. de diámetro y un área superficial de 20.70 m2 , finalmente un sistema de cloración con 10 mamparas de 0.60 m. de ancho, un ancho total de 2.10 m y un largo total de 3.10 m; también se consideró un área para el tratamiento de los lodos producidos en los diversos componentes de la planta de tratamiento, este es un lecho de secado de 9.80 m. de largo y 5.20 m. de ancho. Palabras clave: Límites Máximos Permisibles, tecnología, sistema.es_PE
dc.description.abstractThe present work entitled "Proposal for the design of a water treatment plant With radial flow decantation to reduce Receptor body, Yantalo - Moyobamba district, 2015 ", is the result of the Research, calculations, sizing and design of the analyzes carried out in the waters Of the aforementioned district. The environmental problem that is present in the municipalities of Peru at present is the Environmental contamination from wastewater discharged without any treatment, is In this way, a visit was made to the municipality of Yantaló in order to monitor the Wastewater discharges and make the corresponding characterization of these waters To establish the most appropriate technology using the proposed methodology By the Ministry of the Environment and from this analysis carry out the calculations, Sizing and finally the design of the Wastewater Treatment Plant, Which include pre treatment, primary treatment and tertiary treatment The main parameters for measuring the efficiency of the treatment plant in the Present study, in accordance with D.S No. 003-2010-MINAM. Approves Maximum Limits Allowable for effluents from domestic wastewater treatment plants Or Municipal, published in the Official newspaper of Peru on March 17, 2010, are: BOD5, COD, Suspended Solids, Oils and Fats, Total Coliforms, pH and temperature. By characterizing the wastewater of the district of Yantaló, average results were obtained, Product of 4 samples analyzed at the Regional Water Laboratory - Department of Cajamarca: 184.5 mg / L BOD5, 318.5 mg / l COD, 191.13 SST, 58.25x104 NMP / 100ml of Total Coliforms, 51mg / l of oils and fats, which are found Outside the Maximum Permissible Limits (LMPs) for final discharge. The treatment technology selected for this design proposal of a Wastewater treatment consists of 5 components, Chamber of Rejas, Desander, Grease trap, primary decantation and disinfection (chlorination screens) of the Which have the following values ​​of removal: Grid (BOD5 = 5%, SST = 25%), Degreaser (BOD5 = 15%, SST = 30%), Degreaser (BOD5 = 25%, SST = 30%), Radial flow decanter (BOD5 = 49%, SST = 70%), Disinfection (BOD5 = 15% SST = 0%). Ix The wastewater treatment system, consisting of a 2 m channel, was dimensioned. Long and 0.30 m., With a grid in its central structure at an inclination of 45 °, a 6 m descrambler. With by-pass, and with parshall channel for flow measurement, trap Grease, followed by a 5.13 m radial flow decanter. Diameter and an area Surface of 20.70 m2 , Finally a chlorination system with 10 screens of 0.60 m. Wide, a total width of 2.10 m and a total length of 3.10 m; Was also considered a Area for the treatment of sludge produced in the various components of the plant Of treatment, this is a drying bed of 9.80 m. Long and 5.20 m. Wide. Key words: Permissible maximum limits, technology, system.es_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Nacional de San Martín. Fondo Editoriales_PE
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/deed.es*
dc.sourceRepositorio - UNSMes_PE
dc.subjectDIseño de una planta de tratamiento de aguas residualeses_PE
dc.subjectReducir el grado de contaminaciónes_PE
dc.titlePropuesta de Diseño de una Planta de Tratamiento de Aguas Residuales con Decantación de Flujo Radial para reducir el grado de Contaminación del cuerpo Receptor, Distrito de Yántalo - Moyobambaes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US
thesis.degree.disciplineIngenieria Sanitariaes_PE
thesis.degree.grantorUniversidad Nacional de San Martín. Facultad de Ecologíaes_PE
thesis.degree.nameIngeniero Sanitarioes_PE
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.11.02es_PE
renati.author.dni47982858
renati.advisor.orcidhttps://orcid.org/0000-0003-3755-4093es_PE
renati.advisor.dni08008037
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttps://purl.org/pe-repo/renati/nivel#tituloProfesionales_PE
renati.discipline733016es_PE
renati.jurorAzabache Liza, Yrwin Franciscoes_PE
renati.jurorCaceres Bardalez, Gerardoes_PE
renati.jurorTuesta Casique, Angeles_PE
item.fulltextWith Fulltext-
item.languageiso639-1es-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.grantfulltextopen-
item.cerifentitytypePublications-
item.openairetypeinfo:eu-repo/semantics/bachelorThesis-
Appears in Collections:(Br.) Ingeniería Sanitaria
Files in This Item:
File Description SizeFormat 
TP_ISA_00016_2017.pdf13.68 MBAdobe PDFThumbnail
View/Open
Show simple item record

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons