dc.identifier.citationParedes-Bedezu, A. (2019). Análisis de la resistencia a la compresión del concreto F’c=210 kg/cm2 con adición de vidrio reciclado molido. Tesis para optar el grado de Ingeniero Civil. Facultad de Ingeniería Civil y Arquitectura, Universidad Nacional de San Martín, Tarapoto, Perú.es_PE
dc.identifier.urihttp://hdl.handle.net/11458/3339
dc.description.abstractLa presente investigación tuvo como objetivo principal analizar la resistencia a la compresión del concreto F’c=210 Kg/cm2 con adición de vidrio reciclado molido, mediante el reemplazo parcial en peso del agregado fino en porcentajes del 15%, 20% y 25%, con la finalidad de establecer una comparación entre un concreto convencional y otro con adición de vidrio reciclado molido. Se inició con el análisis de las propiedades físicas y químicas de los agregados pétreos y la elaboración de probetas de concreto y con adición de vidrio reciclado molido en el orden de 5%, 10%, 15%, 20%, 25% y 30% de reemplazo en peso del agregado fino, con la finalidad de obtener los tres porcentajes de adición más adecuados, según la cantidad de vidrio utilizado y la semejanza de la resistencia a la compresión obtenida con el concreto convencional. Seguidamente, se procedió a la rotura de las probetas de concreto mencionadas, obteniendo 15%, 20% y 25% como los porcentajes de adición de vidrio más adecuados. Posteriormente, se elaboró probetas de concreto convencional y modificado con 15%, 20% y 25% de vidrio reciclado molido, y se efectuó las pruebas de resistencia a la compresión a los 7, 14 y 28 días de curado. Al finalizar los ensayos de resistencia a la compresión, se concluyó que usando el 15% de adición de vidrio reciclado molido como reemplazo en peso del agregado fino se obtiene mayor resistencia a la compresión en comparación con el concreto convencional y los demás porcentajes de adición estudiados.es_PE
dc.description.abstractThe following investigation had as main objective to analyze the compressive strength of F'c = 210 Kg / cm2 concrete with the addition of ground recycled glass, by partial replacement in weight of the fine aggregate in percentages of 15%, 20% and 25%, with the purpose of establishing a comparison between a conventional concrete and another with ground recycled glass and. The research began with the analysis of the physical and chemical properties of aggregates and the preparation of conventional concrete specimens, and with the participation in the order of 5%, 10%, 15%, 20%, 25% and 30% of replacement in weight of the fine aggregate, to obtain three percentages of the most suitable addition, according to the amount of glass and the similarity of the compressive strength with conventional concrete. Next, it proceeded to break the concrete specimens mentioned, obtaining 15%, 20% and 25% as the most suitable percentages of glass addition. Subsequently, the test specimens of conventional and modified concrete are made with 15%, 20% and 25% of ground recycled glass, and the compressive strength tests are carried out at 7, 14 and 28 days of curing. At the end of the compression strength tests, it was concluded that using 15% of the addition of ground recycled glass as weight replacement of the fine aggregate, greater compressive strength was obtained compared to the conventional concrete and the other percentages of addition studied.es_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Nacional de San Martín. Fondo Editoriales_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/deed.eses_PE
dc.sourceRepositorio - UNSMes_PE
dc.subjectVidrio Recicladoes_PE
dc.subjectAgregado finoes_PE
dc.subjectProbeta de concretoes_PE
dc.subjectDiseño de mezclaes_PE
dc.subjectResistencia a la compresiónes_PE
dc.titleAnálisis de la resistencia a la compresión del concreto F’c=210 kg/cm2 con adición de vidrio reciclado molidoes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.disciplineIngeniería Civiles_PE
thesis.degree.grantorUniversidad Nacional de San Martín. Facultad de Ingeniería Civil y Arquitecturaes_PE
thesis.degree.nameIngeniero Civiles_PE
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.01es_PE
renati.author.dni46920318es_PE
renati.advisor.orcidhttps://orcid.org/0000-0002-0043-1869es_PE
renati.advisor.dni01111111es_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttps://purl.org/pe-repo/renati/nivel#tituloProfesionales_PE
renati.discipline732267es_PE
renati.jurorAlarcon Zamora, Jose Evergistoes_PE
renati.jurorReategui Acedo, Ivan Gustavoes_PE
renati.jurorChavez Cachay, Santiagoes_PE
item.fulltextWith Fulltext-
item.languageiso639-1es-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.grantfulltextopen-
item.cerifentitytypePublications-
item.openairetypeinfo:eu-repo/semantics/bachelorThesis-