Please use this identifier to cite or link to this item: http://hdl.handle.net/11458/3714
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorDíaz Visitación, Alfredo Ibán
dc.contributor.authorRodriguez Tuesta, Nils Alaín
dc.date.accessioned2020-08-19T13:42:06Z
dc.date.available2020-08-19T13:42:06Z
dc.date.issued2019
dc.identifier.citationRodriguez-Tuesta, N. A. (2019). Evaluación de la eficiencia de un sistema de filtro biológico en la remoción de los contaminantes de las aguas residuales domésticas, Sector Las Lomas, Moyobamba, 2015 - 2016. Tesis para optar el grado de Ingeniero Ambiental. Facultad de Ecología, Universidad Nacional de San Martín, Tarapoto, Perú.es_PE
dc.identifier.urihttp://hdl.handle.net/11458/3714
dc.description.abstractEn la presente investigación se evaluó la eficiencia de un sistema de filtro biológico en la remoción de contaminantes del agua residual doméstica. Se basó en un tanque dividido en tres compartimientos, el primero sirvió de sedimentador para eliminar los sólidos arrastrados por el agua; el segundo contenía el medio filtrante donde se adherían las bacterias que trataban el agua; el tercero se rellenó con arena, esto ayudó a clarificar el agua. El sistema operó con un caudal constante de 42.43 mL/seg en promedio y con los muestreos realizados a los 40, 55, 71 y 91 días de tratamiento se determinó el porcentaje de eficiencia del sistema de filtro biológico. En la DBO5 se observa que la mayor eficiencia con 85.40 %, se realizó a los 40 días de tratamiento, con concentraciones de 685 mg/L en el afluente y 100 mg/L en el efluente. En la DQO, la mayor eficiencia con 82.36 % también se dio a los 40 días, con concentraciones de 1100 mg/L en el afluente y 194 mg/L en el efluente. En los SST la mayor eficiencia con 81.27 % también se dio a los 40 días, con concentraciones de 785 mg/L en el afluente y 147 mg/L en el efluente. En los Coliformes Termotolerantes con concentraciones de 6180 UFC/100 mL en el afluente y 484 UFC/100 mL en el efluente, la mayor eficiencia con 97.17 % se dio a los 91 días respectivamente. Estos resultados indican que el sistema utilizado es eficiente, disminuyendo la concentración de los contaminantes y cumpliendo con los LMP para los efluentes de plantas de tratamiento de aguas residuales domesticas como se indica en el D.S Nº 003-2010-MINAM.es_PE
dc.description.abstractIn the present investigation the efficiency of a biological filter system for the removal of contaminants from domestic wastewater was evaluated. It was based on a tank divided into three compartments, the first served as a settler to remove solids carried by water; the second contained the filter medium where the bacteria that treated the water were adhered; the third was filled with sand, this helped to clarify the water. The system operated with a constant flow rate of 42.43 mL / sec on average and with the sampling performed at 40, 55, 71 and 91 days of treatment the percentage of efficiency of the biological filter system was determined. In BOD5 it is observed that the highest efficiency with 85.40%, was performed after 40 days of treatment, with concentrations of 685 mg / L in the affluent and 100 mg / L in the effluent. In COD, the highest efficiency with 82.36% was given at 40 days, with concentrations of 1100 mg / L in the affluent and 194 mg / L in the effluent. In the TSS, the highest efficiency with 81.27% also occurred at 40 days, with concentrations of 785 mg / L in the affluent and 147 mg / L in the effluent. In the Thermotolerant Coliforms with concentrations of 6180 CFU / 100 mL in the affluent and 484 CFU / 100 mL in the effluent, the highest efficiency with 97.17% occurred at 91 days respectively. These results indicate that the system used is efficient, decreasing the concentration of pollutants and complying with the LMP for effluents from domestic wastewater treatment plants as indicated in D.S No. 003-2010-MINAM.es_PE
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Nacional de San Martín. Fondo Editoriales_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/deed.eses_PE
dc.sourceUniversidad Nacional de San Martín - Tarapotoes_PE
dc.sourceRepositorio - UNSMes_PE
dc.subjectAgua residuales_PE
dc.subjectRemoción de contaminanteses_PE
dc.subjectFiltro biológicoes_PE
dc.subjectEficienciaes_PE
dc.titleEvaluación de la eficiencia de un sistema de filtro biológico en la remoción de los contaminantes de las aguas residuales domésticas, Sector Las Lomas, Moyobamba, 2015 - 2016es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.disciplineIngeniería Ambientales_PE
thesis.degree.grantorUniversidad Nacional de San Martín. Facultad de Ecologíaes_PE
thesis.degree.nameIngeniero Ambientales_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.07.00es_PE
renati.author.dni47627476
renati.advisor.orcidhttps://orcid.org/0000-0002-9130-7598es_PE
renati.advisor.dni17854925
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttps://purl.org/pe-repo/renati/nivel#tituloProfesionales_PE
renati.jurorAzabache Liza, Yrwin Franciscoes_PE
renati.jurorBances Zapata, Estelaes_PE
renati.jurorCaceres Bardalez, Gerardoes_PE
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeinfo:eu-repo/semantics/bachelorThesis-
item.fulltextWith Fulltext-
item.grantfulltextopen-
item.languageiso639-1es-
Appears in Collections:(Br.) Ingeniería Ambiental
Files in This Item:
File Description SizeFormat 
ING. AMBIENTAL - Nils Alaín Rodriguez Tuesta.pdfagua residual, remoción de contaminantes, filtro biológico, eficiencia.5.29 MBAdobe PDFThumbnail
View/Open
Show simple item record

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons