Please use this identifier to cite or link to this item:
http://hdl.handle.net/11458/3441
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Casas Luna, Santiago Alberto | |
dc.contributor.author | Rodriguez Soria, Yessenia | |
dc.date.accessioned | 2019-08-28T13:56:05Z | |
dc.date.available | 2019-08-28T13:56:05Z | |
dc.date.issued | 2018 | |
dc.identifier.citation | Rodriguez-Soria, Y. (2018). Modelamiento de cloro residual con Watercad en las redes de distribución de agua potable de la ciudad de Rioja, provincia de Rioja para determinar la calidad microbiológica, 2017. Tesis para optar el grado de Ingeniero Sanitario. Facultad de Ecología, Universidad Nacional de San Martín, Tarapoto, Perú. | es_PE |
dc.identifier.uri | http://hdl.handle.net/11458/3441 | |
dc.description.abstract | La presente investigación tiene como objetivo, generar un modelo de simulación del cloro residual, en las redes de distribución de agua potable de la ciudad de Rioja, durante el año 2018; para lo cual se consideraron 146 conexiones de agua para muestrear el cloro residual libre en las redes domiciliarias. En la investigación se utilizó el AutoCad para la elaboración de planos correspondientes para el modelo de simulación y esqueletización de redes de agua potable. Mediante el Arcgis se añadieron las curvas de nivel y con la aplicación del WaterCad se realizó el modelo del cloro residual. Respecto a los resultados, concluimos que actualmente la concentración de cloro residual dentro de las redes de distribución es superior a 0.50 mg/L el cual garantiza un óptimo funcionamiento en la remoción de sustancias patógenas. Concluimos que al realizar la simulación del cloro residual en la ciudad de Rioja se puede observar la continuidad y calidad que llega a cada uno de los usuarios dentro de los límites permisibles para consumo humano ya que la concentración del cloro residual mínimo tomado en campo es 0.53 mg/L y el máximo 0.89 mg/L encontrándose dentro de los límites máximos permisibles según la OMS (0.50 mg/L -5 mg/L) y según el Reglamento de calidad de agua para consumo humano del MINSA- Perú el límite máximo permisible es también 5 mg/L. | es_PE |
dc.description.abstract | The following investigation has as objective, generate a residual chlorine simulation model in the drinking water distribution networks of the Rioja city, during the year 2018, for which 146 water connections were considered to sample the free residual chlorine in the networks domiciliary In the research, the AutoCad was used to prepare the corresponding plans for the model of simulation and skeletonization of drinking water networks. Through the Arcgis the level curves were added and with the application of the WaterCad the residual chlorine model was made. Regarding the results, we conclude that currently the residual chlorine concentration within the distribution networks is higher than 0.50 mg / L, which guarantees an optimal operation in the removal of pathogenic substances. We conclude that when performing the residual chlorine simulation in the of Rioja city, we can observe the continuity and quality that reaches each of the users within the permissible limits for human consumption since the concentration of the minimum residual chlorine taken in the field is 0.53. mg / L and the maximum 0.89 mg / L being within the maximum permissible limits according to the WHO (0.50 mg / L -5 mg / L) and according to the Regulation of quality of water for human consumption of the MINSA-Peru the maximum permissible limit It is also 5 mg / L. | es_PE |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Nacional de San Martín. Fondo Editorial | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/deed.es | es_PE |
dc.source | Repositorio - UNSM | es_PE |
dc.subject | Modelo de simulación, | es_PE |
dc.subject | Cloro residual | es_PE |
dc.subject | Red de distribución de agua potable | es_PE |
dc.title | Modelamiento de cloro residual con Watercad en las redes de distribución de agua potable de la ciudad de Rioja, provincia de Rioja para determinar la calidad microbiológica, 2017 | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.discipline | Ingeniería Sanitaria | es_PE |
thesis.degree.grantor | Universidad Nacional de San Martín. Facultad de Ecología | es_PE |
thesis.degree.name | Ingeniero Sanitario | es_PE |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_PE |
dc.publisher.country | PE | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#2.11.02 | es_PE |
renati.author.dni | 47385535 | |
renati.advisor.orcid | https://orcid.org/0000-0003-3755-4093 | es_PE |
renati.advisor.dni | 08008037 | |
renati.type | https://purl.org/pe-repo/renati/type#tesis | es_PE |
renati.level | https://purl.org/pe-repo/renati/nivel#tituloProfesional | es_PE |
renati.discipline | 733016 | es_PE |
renati.juror | Centurion Tapia, Fabian | es_PE |
renati.juror | Valverde Vera, Mirtha Felicita | es_PE |
renati.juror | Rojas Bardalez, Alfonso | es_PE |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.fulltext | With Fulltext | - |
item.grantfulltext | open | - |
item.languageiso639-1 | es | - |
item.openairetype | info:eu-repo/semantics/bachelorThesis | - |
Appears in Collections: | (Br.) Ingeniería Sanitaria |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
ING. SANITARIA - Yessenia Rodríguez Soria.pdf | Modelo de simulación, cloro residual, red de distribución de agua potable. | 4.78 MB | Adobe PDF | View/Open |
Google ScholarTM
Check
This item is licensed under a Creative Commons License