Please use this identifier to cite or link to this item: http://hdl.handle.net/11458/3668
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorChung Rojas, Carlos Enrique
dc.contributor.authorOrdoñez Davila, Manuel Herick
dc.contributor.authorValdera Santamaria, Jimmy Frans
dc.date.accessioned2020-02-18T14:24:07Z
dc.date.available2020-02-18T14:24:07Z
dc.date.issued2019
dc.identifier.citationOrdoñez-Davila, M. H. & Valdera-Santamaria, J. F. (2019). Estudio hidrogeológico con fines de aprovechamiento hídrico subterráneo del manantial Uchpayacu para consumo humano en el caserío Tres de Octubre, distrito de La Banda de Shilcayo, provincia de San Martín - región San Martín, 2019. Tesis para optar el grado de Ingeniero Civil. Facultad de Ingeniería Civil y Arquitectura, Universidad Nacional de San Martín, Tarapoto, Perú.es_PE
dc.identifier.urihttp://hdl.handle.net/11458/3668
dc.description.abstractEl presente trabajo de investigación se realizó en base a las exigencias y requerimientos del reglamento que exige la Escuela Profesional de Ingeniería Civil de la Universidad Nacional de San Martin por ello ponemos a vuestra disposición la tesis que se titula “Estudio hidrogeológico con fines de aprovechamiento hídrico subterráneo del manantial Uchpayacu para consumo humano en el Caserío Tres de Octubre, Distrito de la Banda de Shilcayo, Provincia de San Martin - Región San Martin, 2019”, que tiene como objetivo realizar un estudio hidrogeológico a partir del método S.E.V en el sector Uchpayacu, con fines de aprovechamiento hídrico subterráneo para consumo humano en el Caserío Tres de Octubre. Este procedimiento consta de aplicar resistencia eléctrica al suelo, por lo cual se caracteriza el tipo de suelo y niveles freáticos, para el planteamiento de esto, es ubicar el área de estudio que tenga registro o antecedentes de tener aguas subterráneas para su posterior aprovechamiento. Al estar situada el área de estudio se localiza estratégicamente los puntos SEV; el método utilizado es el Sondeo Eléctrico Vertical (SEV), se han efectuado un total de nueve sondeos eléctricos verticales con un espaciamiento de 30m por cada electrodo con una apertura total de 90 m. con el fin de estudiar el perfil geoeléctrico de la zona, a una profundidad aproximada de 25 m. El equipo utilizado ha sido el Modelo MILLER 400D que proporciona una lectura directa de la resistencia del suelo, cuenta con un rango de medición de 0.01 Ω a 10M Ω, funciona con un conjunto de baterías alcalinas industriales D – Cell reemplazables, realiza 10000 lecturas individuales por conjunto de baterías y además dispone de filtros de paso de banda de 82.2 Hz. A si mismo se ha contado para la interpretación de datos con el software IPI2WIN obteniendo el número de capas y las resistividades reales del subsuelo. Todo esto nos permitió determinar tipos de suelo, niveles freáticos, curvas isopiezometricas, dirección de flujo, caudal y los parámetros hidrogeológicos.es_PE
dc.description.abstractThis research work was carried out based on the requirements and requirements of the regulations required by the Professional School of Civil Engineering of the National University of San Martin, so we put at your disposal the thesis entitled "Hydrogeological study for the purpose of water use underground of the Uchpayacu spring for human consumption in Caserío Tres de Octubre, District of the Shilcayo Band, San Martin Province - San Martin Region, 2019 ”, which aims to conduct a hydrogeological study from the SEV method in the Uchpayacu sector , with the purpose of underground water use for human consumption in the Tres de Octubre Farmhouse. This procedure consists of applying electrical resistance to the ground, which is why the type of soil and groundwater levels are characterized, for the purpose of this, it is to locate the study area that has a record or history of having groundwater for later use. When the study area is located, the SEV points are strategically located; The method used is the Vertical Electrical Probe (SEV), a total of nine vertical electrical probes have been made with a spacing of 30m for each electrode with a total opening of 90 m. in order to study the geoelectric profile of the area, at an approximate depth of 25 m. The equipment used has been the MILLER 400D Model that provides a direct reading of the ground resistance, has a measuring range of 0.01 Ω to 10M Ω, works with a set of replaceable D-Cell industrial alkaline batteries, performs 10,000 individual readings per set of batteries and also has 82.2 Hz bandpass filters. It has been counted for the interpretation of data with the IPI2WIN software, obtaining the number of layers and the real resistivities of the subsoil. All this allowed us to determine soil types, groundwater levels, piezometric curves, flow direction, flow rate and hydrogeological parameters.es_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Nacional de San Martín. Fondo Editoriales_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/deed.eses_PE
dc.sourceRepositorio - UNSMes_PE
dc.subjectHidrogeologíaes_PE
dc.subjectCaudales_PE
dc.subjectNivel freáticoes_PE
dc.subjectDirección de flujoes_PE
dc.subjectSondeo eléctrico verticales_PE
dc.subjectResistencia eléctricaes_PE
dc.titleEstudio hidrogeológico con fines de aprovechamiento hídrico subterráneo del manantial Uchpayacu para consumo humano en el caserío Tres de Octubre, distrito de La Banda de Shilcayo, provincia de San Martín - región San Martín, 2019es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.disciplineIngeniería Civiles_PE
thesis.degree.grantorUniversidad Nacional de San Martín. Facultad de Ingeniería Civil y Arquitecturaes_PE
thesis.degree.nameIngeniero Civiles_PE
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_PE
dc.publisher.countryPEes_PE
renati.author.dni75853333es_PE
renati.author.dni70992674es_PE
renati.advisor.orcidhttps://orcid.org/0000-0002-3646-5550es_PE
renati.advisor.dni01089135es_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttps://purl.org/pe-repo/renati/nivel#tituloProfesionales_PE
renati.discipline732267es_PE
renati.jurorPizarro Baldera, Jose Del Carmenes_PE
renati.jurorGarcia Ramirez, Ernesto Eliseoes_PE
renati.jurorHuaman Torrejon, Carlos Segundoes_PE
item.fulltextWith Fulltext-
item.languageiso639-1es-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.grantfulltextopen-
item.cerifentitytypePublications-
item.openairetypeinfo:eu-repo/semantics/bachelorThesis-
Appears in Collections:(Br.) Ingeniería Civil
Files in This Item:
File Description SizeFormat 
CIVIL - Manuel Herick Ordoñez Davila & Jimmy Frans Valdera Santamaría.pdfHidrogeología, Caudal, Nivel freático, Dirección de flujo, Sondeo eléctrico vertical, Resistencia eléctrica.9.75 MBAdobe PDFThumbnail
View/Open
Show simple item record

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons