Please use this identifier to cite or link to this item: http://hdl.handle.net/11458/4673
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorAzabache Liza, Yrwin Franciscoes_PE
dc.contributor.authorSilva Flores, Jhonyes_PE
dc.date.accessioned2023-01-10T16:24:28Z-
dc.date.available2023-01-10T16:24:28Z-
dc.date.issued2022-08-18-
dc.identifier.citationSilva-Flores, J. (2022). Evaluación de la eficiencia del biodigestor comercial en el tratamiento de las aguas residuales domiciliarias. Tesis para optar el grado de Ingeniero Sanitario. Facultad de Ecología, Universidad Nacional de San Martín, Tarapoto, Perú.es_PE
dc.identifier.urihttp://hdl.handle.net/11458/4673-
dc.description.abstractEl presente trabajo se ejecutó en el CC. PP. Yarinal, distrito de Pardo Miguel, San Martín; con la finalidad de evaluar la eficiencia de un biodigestor comercial en el tratamiento de aguas residuales domésticas de la zona. Teniendo en cuenta los componentes del biodigestor se realizó la caracterización física, química y biológica de las aguas, para así determinar la efectividad del mismo. La parte experimental del presente trabajo, se desarrolló en el sector Yarinal, en donde se tomaron muestras 4 muestras, de manera semanal, durante un mes, para así poder realizar los respectivos análisis. Como resultados se obtuvo los siguientes datos de eficiencia por cada parámetro evaluado en la primera etapa del proceso preliminar : DBO – 51.48%, DQO – 46%, Sólidos en Suspensión Totales – 52.84%, Coliformes Fecales (termotolerantes) – 87.60%, Oxígeno Disuelto 269%, Fosfatos – 27; para lo cual se concluye que el biodigestor no está siendo eficiente con el proceso de tratamiento que se evaluó en una primera etapa antes del pozo de absorción y no cumple con las especificaciones de los parámetros de descarga de efluentes residuales. Esto puede darse debido a diversos factores; el biodigestor no cumple con lo especificado y no es apto para el tratamiento, o está siendo operada de manera incorrecta. Sin embargo, cumple con la reducción de los agentes contaminantes presentes en las aguas residuales, pero no de la manera esperada.es_PE
dc.description.abstractThe present work was carried out at the CC. PP. Yarinal, district of Pardo Miguel, San Martin; in order to evaluate the efficiency of a commercial biodigester in the treatment of domestic wastewater in the area. Considering the components of the biodigester, a physical, chemical and biological characterization of the water was performed in order to determine its effectiveness. The experimental part of this study was carried out in the Yarinal sector, where 4 samples were taken weekly for a month in order to perform the respective analyses. As results, the following efficiency data was obtained for each parameter evaluated in the first stage of the preliminary process: BOD - 51.48%, COD - 46%, Total Suspended Solids - 52.84%, Fecal Coliforms (thermotolerant) - 87. 60%, Dissolved Oxygen 269%, Phosphates - 27. It is therefore concluded that the biodigester is not being efficient with the treatment process that was evaluated in a first stage before the absorption pit and does not comply with the specifications of the waste effluent discharge parameters. This may be due to several factors: the biodigester does not meet specifications and is not suitable for treatment, or it is being operated incorrectly. It does, however, reduce the pollutants present in the wastewater, but not as expected.es_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Nacional de San Martín. Fondo Editoriales_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/deed.eses_PE
dc.sourceRepositorio - UNSMes_PE
dc.subjectBiodigestores_PE
dc.subjectFísicaes_PE
dc.subjectQuímicaes_PE
dc.subjectBiológicaes_PE
dc.subjectContaminaciónes_PE
dc.subjecteficienciaes_PE
dc.titleEvaluación de la eficiencia del biodigestor comercial en el tratamiento de las aguas residuales domiciliariases_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.disciplineIngeniería Sanitariaes_PE
thesis.degree.grantorUniversidad Nacional de San Martín. Facultad de Ecologíaes_PE
thesis.degree.nameIngeniero Sanitarioes_PE
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#1.06.13es_PE
renati.author.dni72100169-
renati.advisor.orcidhttps://orcid.org/0000-0003-1396-9745es_PE
renati.advisor.dni18070745-
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttps://purl.org/pe-repo/renati/nivel#tituloProfesionales_PE
renati.discipline733016es_PE
renati.jurorRojas Bardalez, Alfonsoes_PE
renati.jurorDiaz Visitacion, Alfredo Ibanes_PE
renati.jurorRodriguez Perez, Luis Eduardoes_PE
item.openairetypeinfo:eu-repo/semantics/bachelorThesis-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.languageiso639-1es-
item.fulltextWith Fulltext-
item.grantfulltextopen-
Appears in Collections:(Br.) Ingeniería Sanitaria
Files in This Item:
File Description SizeFormat 
Ing. Sanitaria - Jhony Silva Flores.pdf5.56 MBAdobe PDFView/Open
Formato de Autorización NO EXCLUSIVA.pdf509.25 kBAdobe PDFView/Open
Reporte turnitin.pdf17.74 MBAdobe PDFView/Open
Show simple item record

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons