Please use this identifier to cite or link to this item: http://hdl.handle.net/11458/4885
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorAzabache Liza, Yrwin Franciscoes_PE
dc.contributor.authorLumba Noriega, Menen Pooles_PE
dc.date.accessioned2023-03-30T13:30:40Z-
dc.date.available2023-03-30T13:30:40Z-
dc.date.issued2022-12-20-
dc.identifier.citationLumba-Noriega, M. P. (2022). Implementación de un sistema de tratamiento primario para la remoción de parámetros físico-químicos generado por aguas residuales del lavadero AQUA-Moyobamba. Tesis para optar el grado de Ingeniero Sanitario. Facultad de Ecología, Universidad Nacional de San Martín, Tarapoto, Perú.es_PE
dc.identifier.urihttp://hdl.handle.net/11458/4885-
dc.description.abstractEsta investigación tuvo como objetivo implementar un sistema de tratamiento primario de aguas residuales para la remoción de parámetros físico-químicos generadas por las actividades del lavado automovilístico; para ello se realizó el estudio y la determinación del sistema de tratamiento a implementar, el cual consistió en un trampa de grasas que hacía las veces de sedimentador seguido por un filtro de grava y arena, al cual se le agregó carbón activado artesanal para mejorar la eficiencia de remoción de los parámetros; los muestreos se realizaron cada 15 días por un periodo de 2 meses, obteniendo datos iniciales como: pH (9,73); DBO (223 mg/L); DQO (500 mg/L); SST (650 mg/L) y Aceites y grasas (258 mg/L); en los muestreos tomados después de la implementación del sistema de tratamiento, se obtuvieron datos como: pH (8,52); DBO (126 mg/L); DQO (200 mg/L); SST (220 mg/L) y aceites y grasas (82 mg/L); evidenciando así resultados significativos en la eficiencia de remoción de: DBO (43 %), DQO (60 %), SST (66 %) y Aceites y grasas (68 %). La evaluación de la implementación del sistema de tratamiento, demuestra que tiene efecto en la remoción de los parámetros físico-químicos, llegando a concluir que, con la construcción de un sistema de tratamiento se ha logrado reducir de manera significativa en un 68 % los contaminantes presentes en el agua residual, para poder ser vertidos en el alcantarillado.es_PE
dc.description.abstractThe objective of this research was to implement a primary wastewater treatment system for physicochemical parameters removal generated by car washing activities. For this purpose, a study was conducted to determine the treatment system to be implemented, which consisted of a grease trap that served as a settling tank followed by a gravel and sand filter, to which artisanal activated carbon was added to improve the removal efficiency of the parameters. Sampling was carried out every 15 days for a period of 2 months, obtaining initial data such as: pH (9.73); BOD (223 mg/L); COD (500 mg/L); TSS (650 mg/L) and Oils and fats (258 mg/L). In the samples collected after the implementation of the treatment system, the following data were obtained: pH (8.52); BOD (126 mg/L); COD (200 mg/L); TSS (220 mg/L) and Oils and fats (82 mg/L), thus showing significant results in the removal efficiency of: BOD (43 %), COD (60 %), TSS (66 %) and Oils and fats (68 %). The evaluation of the implementation of the treatment system shows that it does have an effect on the removal of the physical-chemical parameters, concluding that, with the construction of a treatment system, a significant reduction of 68% of the pollutants present in the wastewater has been achieved, enabling it to be discharged into the sewage system.es_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Nacional de San Martín. Fondo Editoriales_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/deed.eses_PE
dc.sourceRepositorio - UNSMes_PE
dc.subjectSistemas de tratamientoes_PE
dc.subjectLavaderos automovilísticoses_PE
dc.subjectEficienciaes_PE
dc.titleImplementación de un sistema de tratamiento primario para la remoción de parámetros físico-químicos generado por aguas residuales del lavadero AQUA-Moyobambaes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.disciplineIngeniería Sanitariaes_PE
thesis.degree.grantorUniversidad Nacional de San Martín. Facultad de Ecologíaes_PE
thesis.degree.nameIngeniero Sanitarioes_PE
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#1.06.13es_PE
renati.author.dni71012003-
renati.advisor.orcidhttps://orcid.org/0000-0003-1396-9745es_PE
renati.advisor.dni18070745-
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttps://purl.org/pe-repo/renati/nivel#tituloProfesionales_PE
renati.discipline733016es_PE
renati.jurorValverde Vera, Mirtha Felicitaes_PE
renati.jurorRodriguez Perez, Luis Eduardoes_PE
renati.jurorCordova Vasquez, Alexes_PE
item.fulltextWith Fulltext-
item.languageiso639-1es-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.grantfulltextopen-
item.cerifentitytypePublications-
item.openairetypeinfo:eu-repo/semantics/bachelorThesis-
Appears in Collections:(Br.) Ingeniería Sanitaria
Files in This Item:
File Description SizeFormat 
ING. SANITARIA - Menen Pool Lumba Noriega.pdf4.14 MBAdobe PDFView/Open
Formato de autorización NO EXCLUSIVA.pdf410.49 kBAdobe PDFView/Open
Reporte turnitin .pdf18.69 MBAdobe PDFView/Open
Show simple item record

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons