dc.identifier.citationVela-Rios, I. M. (2018). Eficiencia de un Tanque Imhoff-HA a escala, para mejorar la calidad de las aguas servidas municipales del distrito de Habana, Moyobamba. Tesis para optar el grado de Ingeniero Sanitario. Facultad de Ecología, Universidad Nacional de San Martín, Tarapoto, Perú.es_PE
dc.identifier.urihttp://hdl.handle.net/11458/3164
dc.description.abstractLa presente tesis se planteó con la finalidad de comprobar la eficiencia de un tanque imhoff-HA como parte del mejoramiento del tratamiento de las aguas servidas municipales, en este caso del distrito de Habana. Para lo cual se implementó dos unidades experimentales; la primera unidad fue de un tanque imhoff con 1.48 m de largo, 1.13 m de ancho y 1.02 m de profundidad y la segunda unidad de un humedal artificial de flujo subsuperficial horizontal con 1.83 m de largo, 0.77 m de ancho, 0.57 de profundidad y pendiente de 1%, sembrada con Phragmites australis (carrizo), se utilizó grava de 5.0 cm de diámetro como medio granular del humedal. El estudio se empezó en campo, con la construcción de las unidades experimentales; operación, monitoreo, localización y toma de muestras al ingreso del agua residual de tanque imhoff (afluente), ingreso al humedal artificial (efluente 1) y salida del agua residual del humedal artificial (efluente 2), para pasar posteriormente a una etapa de análisis de los parámetros tanto en el laboratorio (nitratos, fosfatos y DBO5) como en el lugar donde se encontraban las unidades experimentales (pH, turbiedad, sólidos totales en suspensión, temperatura). Se reportó una remoción promedio final de 84.14% para turbidez, 94.82% para sólidos en suspensión, 35.78% para nitratos, 65.57% para fosfatos y 93.99% para DBO5. Con los resultados obtenidos se demostraron que trabajando con un sistema integrado de tanque imhoff y humedal artificial, removieron significativamente la concentración de los parámetros evaluados, pues sus valores están dentro de los rangos de Límites Máximos Permisibles (LMP) establecidos para los efluentes de plantas de tratamiento de aguas residuales domésticas o municipales, asimismo se tomó como referencia para parámetros como turbidez, nitratos y fosfatos los estándares de calidad ambiental (ECA’s). Finalmente, debido a la remoción significativa y bajos costos de operación y mantenimiento, el sistema integrado por tanque imhoff y humedal artificial podría ser utilizado en zonas rurales que carezcan de alcantarillado público.es_PE
dc.description.abstractThe following thesis was raised in order to verify the efficiency of an imhoff-HA tank as part of the improvement of municipal wastewater treatment, in this case the district of Havana. For which two experimental units were implemented; the first unit was an imhoff tank with 1.48 m long, 1.13 m wide and 1.02 m deep and the second unit of an artificial wetland with horizontal subsurface flow 1.83 m long, 0.77 m wide, 0.57 deep and slope of 1%, seeded with Phragmites australis (reed), 5.0 cm diameter gravel was used as the granular medium of the wetland. The study was started in the field, with the construction of the experimental units; operation, monitoring, location and sampling at the entrance of the residual water from the imhoff tank (tributary), entry to the artificial wetland (effluent 1) and exit of the residual water from the artificial wetland (effluent 2), to later pass to an analysis stage of the parameters both in the laboratory (nitrates, phosphates and BOD5) and in the place where the experimental units were located (pH, turbidity, total suspended solids, temperature). A final average removal of 84.14% was reported for turbidity, 94.82% for suspended solids, 35.78% for nitrates, 65.57% for phosphates and 93.99% for BOD5. With the results obtained it was demonstrated that working with an integrated system of imhoff tank and artificial wetland, they significantly removed the concentration of the evaluated parameters, since their values are within the ranges of Maximum Permissible Limits (LMP) established for the effluents of plants of treatment of domestic or municipal wastewater, also standards for environmental quality (ECA's) were taken as reference for parameters such as turbidity, nitrates and phosphates. Finally, due to the significant removal and low operation and maintenance costs, the system integrated by imhoff tank and artificial wetland could be used in rural areas that lack public sewage.es_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Nacional de San Martín. Fondo Editoriales_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/deed.eses_PE
dc.sourceRepositorio - UNSMes_PE
dc.subjectPlantas de tratamiento,es_PE
dc.subjectAguas residualeses_PE
dc.subjectTratamiento de aguas residualeses_PE
dc.subjectNitratoses_PE
dc.subjectFosfatoses_PE
dc.subjectHumedaleses_PE
dc.subjectUso de aguas residualeses_PE
dc.titleEficiencia de un Tanque Imhoff-HA a escala, para mejorar la calidad de las aguas servidas municipales del distrito de Habana, Moyobambaes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.disciplineIngeniería Sanitariaes_PE
thesis.degree.grantorUniversidad Nacional de San Martín. Facultad de Ecologíaes_PE
thesis.degree.nameIngeniero Sanitarioes_PE
dc.type.versionhttps://purl.org/pe-repo/ocde/ford#2.11.02es_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.11.02es_PE
renati.author.dni45670403
renati.advisor.orcidhttps://orcid.org/0000-0003-3755-4093es_PE
renati.advisor.dni08008037
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttps://purl.org/pe-repo/renati/nivel#tituloProfesionales_PE
renati.discipline733016es_PE
renati.jurorAzabache Liza, Yrwin Franciscoes_PE
renati.jurorDiaz Visitacion, Alfredo Ibanes_PE
renati.jurorCaceres Bardalez, Gerardoes_PE
item.fulltextWith Fulltext-
item.languageiso639-1es-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.grantfulltextopen-
item.cerifentitytypePublications-
item.openairetypeinfo:eu-repo/semantics/bachelorThesis-
Appears in Collections:(Br.) Ingeniería Sanitaria
Files in This Item:
File Description SizeFormat 
SANITARIA - Ingry Margoth Vela Rios.pdfPlantas de tratamiento, aguas residuales, tratamiento de aguas residuales, nitratos, fosfatos, humedales, uso de aguas residuales.9.83 MBAdobe PDFThumbnail
View/Open
Show simple item record

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons